Waterproofing

    Wet room tanking and waterproofing explained

    Tanking is the single component that decides whether a wet room lasts. This page explains what the membrane is, how far it has to reach, and why installations fail.

    What is wet room tanking?

    Tanking is a continuous waterproof membrane bonded to the floor and walls beneath the tiles. It reinforces every corner, junction and pipe penetration, and it — not the tile or the grout — is what keeps water out of the floor structure.

    The build-up

    What sits between the water and your floor joists

    A wet room floor is a layered system. Remove or interrupt any one layer and the system stops working.

    1. 1

      1. Structural deck

      Concrete slab, or joists with a rigid tile backer board replacing the original timber deck. It must not flex under load.

    2. 2

      2. Falls and former

      A prefabricated sloping former or a screeded gradient directing water to the drain, typically between 1:80 and 1:40.

    3. 3

      3. Primer

      Manufacturer-matched primer that gives the membrane something to bond to and controls substrate absorbency.

    4. 4

      4. Reinforced junctions

      Waterproof tape bedded into the membrane at every internal corner, wall-to-floor junction, drain flange and pipe penetration.

    5. 5

      5. The membrane

      Liquid-applied in two coats or a bonded sheet, continuous across the whole floor and up the wet-zone walls.

    6. 6

      6. Tile, adhesive and grout

      Flexible adhesive and grout over the cured membrane. This layer is the wearing surface, not the waterproofing.

    Coverage

    How far the membrane has to go

    Coverage is where good and bad installations separate. A wet room has no tray edge to contain water, so the water goes wherever the floor lets it. Our standard specification is:

    • The entire floor, wall to wall, not just the shower zone.
    • A minimum 100mm upstand onto every wall, lapped into the floor membrane.
    • Full-height tanking to 1,800mm or more on all walls inside the shower zone.
    • Reinforcing tape at every internal corner and every change of plane.
    • Collars at every pipe penetration and around the drain flange.
    • Sealed threshold at the door so water cannot track under the frame.

    The membrane is left to cure for the full time the manufacturer states before tiling starts. Rushing that cure is a silent failure — the tiles go on, the room looks finished, and the membrane never reaches its rated performance.

    Failure modes

    The five reasons wet rooms leak

    • Partial tanking: the shower corner is sealed and the rest of the floor is bare substrate.
    • Unreinforced corners: the membrane spans an internal angle with no tape, then cracks as the building moves.
    • Flexing deck: tiles laid over a timber floor that was never stiffened, so the adhesive bed and membrane crack.
    • Wrong or absent falls: water sits on the floor instead of draining, and standing water finds every weakness.
    • Mixed systems: primer from one brand, membrane from another, tape from a third, and no valid warranty on any of it.
    Glasgow specifics

    Waterproofing in Glasgow properties

    In a Glasgow tenement, a floor leak does not damage your property first — it damages the flat below. That changes the risk calculation entirely, and it is why we tank tenement wet rooms to a higher upstand than a ground-floor bungalow needs and flood-test before handover.

    Glasgow's humidity also means surfaces stay damp for longer between uses. Constant low-level moisture attacks grout and silicone before it attacks the membrane, so extraction and membrane specification are part of the same conversation. See the ventilation guide.

    Common questions

    Tanking questions

    Tanking is the application of a continuous waterproof membrane to the floor and walls of a wet room before tiling. The membrane bonds to the substrate, is reinforced at every corner, junction and pipe penetration, and forms the layer that actually keeps water out of the structure.

    No. Tiles and grout are water-resistant, not waterproof. Water passes through grout joints over time, so a wet room without a tanking membrane beneath the tiles will eventually wet the substrate and the structure below.

    The whole floor should be tanked, with the membrane carried at least 100mm up every wall and to a minimum of 1,800mm high within the shower zone and on any wall regularly wetted. Partial tanking of the shower corner alone is the most common cause of failure.

    Liquid-applied bonded membranes and sheet membranes both perform when installed to the manufacturer's specification. Sheet systems give a guaranteed thickness and can be tiled sooner; liquid systems handle complex shapes and penetrations more easily. The system, primer, tape and adhesive should all come from one manufacturer so the warranty holds.

    Wet rooms leak because the membrane is missing, discontinuous, or unsupported at a movement joint. The recurring causes are untanked floors outside the shower zone, unreinforced internal corners, unsealed pipe penetrations, insufficient floor fall leaving standing water, and a rigid tile finish over a flexing timber deck.