Tenements & flats

    Wet rooms in Glasgow tenement flats

    Glasgow's tenement stock puts a timber floor, a shared soil stack and a neighbour's ceiling between your shower and a very expensive problem. Here is how a tenement wet room is done properly.

    What is different about a tenement wet room?

    A tenement wet room sits on suspended timber joists above another household, so the floor must be stiffened, the drain must fit a shallow build-up, the waste must reach the existing soil stack at a workable gradient, and the entire floor must be tanked and flood-tested — not just the shower zone.

    Four constraints

    What decides whether the job is straightforward

    Every tenement survey answers the same four questions before we can price the work.

    1. 1

      Joist depth and direction

      Joist depth sets how much build-up is available for the former and drain. Direction sets where a linear drain can run without notching across the span.

    2. 2

      Distance to the soil stack

      The waste needs a continuous fall to the stack. The further the run, the more depth it consumes, which competes with the depth needed for the falls.

    3. 3

      Access to the ceiling below

      Some connections are far simpler with access from the flat underneath. Where that is not available, the design works within the floor void from above.

    4. 4

      Condition of the existing floor

      Pre-1919 decking is rarely suitable for tiling. We usually replace it with a rigid tile backer board fixed to the joists to eliminate flex.

    Build detail

    How we build into a timber floor

    The shower zone is formed with a purpose-made recessed former set between the joists, rather than by cutting a slope into the structure. The former arrives with the fall already built in, which removes the biggest source of error on site and keeps the notching within acceptable limits.

    Around the former, the deck is replaced with a rigid board bedded and screwed at close centres so the floor cannot deflect. Deflection, not water pressure, is what cracks a tiled wet room floor. Once the deck is solid, the primer, reinforcing tape and bonded membrane are applied across the full floor and up the walls.

    Flood testing

    On tenement jobs we flood-test the tanked floor before tiling. The drain is temporarily blocked, water is held on the membrane, and the level is checked over time. Finding a pinhole at that stage costs an hour; finding it after the neighbour's ceiling stains costs a great deal more.

    Protecting the flat below

    We ask you to let the downstairs neighbour know the dates. It is a courtesy that has practical value — if anything appears on their ceiling during or after the work, we want to hear about it immediately rather than months later. See the tanking specification we work to.

    Ownership & regulation

    Deeds, factors and building standards

    • Check your title deeds before any work touching the soil stack or common drainage — these are usually shared elements.
    • Where a factor manages the building, inform them of the work and the dates in writing.
    • The Tenements (Scotland) Act 2004 governs shared maintenance and access where deeds are silent.
    • Like-for-like replacement of sanitary fittings is generally exempt work under Scottish building standards.
    • A building warrant is required for structural alterations, new drainage arrangements or forming a bathroom in a room not previously used as one.
    • Confirm any warrant question with Glasgow City Council Building Standards before work begins — the responsibility sits with the property owner.
    Common questions

    Tenement wet room questions

    Yes. A wet room can be installed in a tenement flat provided the floor build-up can accommodate a drain and falls, and the waste can be routed to the existing soil stack at an adequate gradient. The joists are assessed first, because notching them beyond permitted limits is not acceptable.

    Internal work within your own flat generally does not require consent from other owners, but title deeds and the Tenements (Scotland) Act 2004 govern shared elements such as the soil stack and common drainage. Check your title deeds before any work that touches a common pipe, and inform the factor where one is appointed.

    A tenement wet room typically needs 40mm to 90mm of build-up for the former, drain body and tile. Shallow-profile drains and low-height formers are used where joist depth is limited, and the finished floor level is often raised slightly at the door threshold rather than cutting deeper into joists.

    A correctly tanked wet room does not leak into the flat below. Risk is controlled by tanking the entire floor rather than the shower zone alone, reinforcing every junction, forming adequate falls, and flood-testing the floor before tiling and again before handover.

    Replacing sanitary fittings in an existing bathroom is generally exempt from building warrant requirements in Scotland. A warrant becomes necessary when the work is structural, forms a bathroom in a room not previously used as one, or alters drainage beyond the existing installation. Confirm your specific case with Glasgow City Council Building Standards.

    Converting a tenement bathroom?

    Tell us the room, the floor type and what the wet room is for. You get a written, itemised quote — no pressure, no call centre.